Enforcement Note:Luton Borough Council enforces the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, requiring all private landlords to hold a valid EICR for each rental property, renewed every five years. Commercial premises must comply with the Electricity at Work Regulations 1989, enforced by the Health and Safety Executive. An unsatisfactory EICR with C1 or C2 codes must be remediated and re-tested before a satisfactory certificate can be issued.
Every consumer unit and distribution board inspected for correct labelling, adequate IP rating, and proper discrimination. RCDs tested for trip time and operating current.
Earth fault loop impedance (Zs) measured at every circuit to verify protective devices will operate within disconnection times.
Every circuit tested for insulation resistance (minimum 1MΩ at 500V DC) to identify cable degradation, moisture ingress, or damaged insulation.
An immediate risk of injury exists. The defect must be rectified or made safe immediately. Examples include exposed live conductors, absent earthing, or failed protective devices.
A fault that could become dangerous under certain conditions. Urgent remedial work is required, typically within 28 days. Common examples include overloaded circuits or deteriorated wiring.
Not immediately dangerous, but an upgrade would improve safety. C3 items alone will not result in an unsatisfactory report — they are recommendations for future improvement.
The inspector has identified an area requiring additional investigation before a final classification can be assigned — often involving concealed wiring or inaccessible areas.
From verified commercial property clients across the UK
Tony Mann
Milton Keynes · Local Guide
First class service. From the moment we got in touch with ProConform it was obvious this was a professional company who took the time to understand our requirements. Their service has been excellent, with minimum impact to our day to day operations and taken the overhead of our compliance obligations.
Jordan Cleghorn
Verified Customer
I asked ProConform to help turn my garage into a space for the dogs — somewhere to hose them down and keep them warm afterwards. They installed a new consumer unit, added lighting and a couple of sockets, and the finish is really tidy. Communication was clear from start to finish, they arrived when they said they would, and they tested everything before leaving. The workmanship is spot on and the place was left clean.
Taya Cleghorn
Bedford · Verified Customer
Excellent work, provided a full explanation of what was required and delivered the work at a time that was suitable to our business. Highly recommend.
Marina Azhar
London · Verified Customer
I've used Richard three times now, and each experience has been outstanding. Most recently, he installed an induction hob and replaced a wired bathroom mirror. As with previous work — including replacing our garden lights and installing a power supply for an awning — everything was completed on time and to an exceptional standard. Richard's attention to detail, professionalism, and skill are second to none.
Commercial properties typically require an EICR every 5 years under BS 7671. The previous inspector may recommend a shorter interval depending on the condition of the installation. Certain environments in Luton such as industrial units or properties with high electrical demand may need more frequent inspection.
C1 indicates danger present requiring immediate action. C2 means potentially dangerous and requires urgent remedial work. C3 is an improvement recommended but not immediately dangerous. FI means further investigation is required. A C1 or C2 finding results in an unsatisfactory EICR.
An unsatisfactory EICR with C1 or C2 codes means the installation has dangerous or potentially dangerous faults. You have a legal duty under the Electricity at Work Regulations 1989 to maintain safe electrical systems. The responsible person must arrange remedial works — typically immediately for C1 and within 28 days for C2.
You receive a full Electrical Installation Condition Report compliant with BS 7671, including schedule of inspections, schedule of test results, and a summary of observations with classification codes. A PDF copy is provided for your records.
BS 5839-1 compliant fire alarm testing and servicing for Luton commercial premises.
Learn moreBS 5266-1 emergency lighting duration tests for Luton offices, retail units and care homes.
Learn moreCounty-wide EICR testing across Bedfordshire — Luton, Dunstable, Bedford and more.
Learn moreFounder & Lead Electrical Engineer · 20+ years' experience
Every EICR in Luton is carried out to BS 7671 standards by our NICEIC-approved engineers and overseen by Richard, who has spent more than two decades inspecting and certifying electrical installations across Bedfordshire and the surrounding region.
Whether you manage a single office or a portfolio of commercial properties across Luton and Bedfordshire — thorough BS 7671 compliant inspections with clear reporting and fast turnaround.
NICEIC Approved Contractor · BS 7671 Compliant · Covering Luton & Surrounding Areas